- Field log·6:38a·JOB-2212JOB-2212
Morning huddle · 12-crew concrete pour
Crew of 12 on site. Slab pour grid B/3–B/8 kicked off 6:30a. Pump truck on time. Two flaggers staged at north gate for concrete trucks.
RMRay Malveaux · Superintendent - Weather·7:12a·Advisory
Rain advisory issued for Orleans Parish
60% chance of rain 2p–5p. Wind SW 12 mph. Temp 78° rising to 86°. Exterior pours and roofing work at risk on JOB-2212 and JOB-2214.
N+NWS + on-site sensor · Weather feed - Crew·7:45aJOB-2212
Clock-in complete · 84 workers across 6 jobs
JOB-2212: 34 workers (Delta Concrete 12, Ironworks 6, LL crew 8, Electric 5, Mech 3). Two no-shows from Ironworks — foreman notified.
T(Timekeeper (auto) · Kiosk / geofence - Delivery·8:20a·PO-4471JOB-2211
Delivery received · 42 units Type X drywall
Staged floor 2, east stair. BOL signed. Damaged corner on 3 sheets — photo attached, credit request opened with supplier.
ScSite clerk — Tanya P. · Receiving - AI copilot·8:55a·AI · recommendJOB-2212
Suggested action · protect pour before weather turns
Given rain probability >55% at 2p and the pour placed 6:30a, curing surface will be vulnerable. Recommend covering B/3–B/8 by 1:30p. Draft directive prepared for Ray M.
AFAI Field Copilot · Auto-generated - RFI / Block·9:20a·RFI-088JOB-2212
Blocked · awaiting RFI-088 (fire alarm layout)
3rd floor east rough-in complete. West rough-in halted pending fire alarm device layout. RFI-088 aging 6 days with Cypress & Iron Architects.
ARAna Rivera · Electrical foreman - Photos·10:02aJOB-2213
Progress photos · plaster restoration bay 2
12 photos uploaded from bay 2 & 3. Original medallion cleaned; sample skim coat approved by preservation consultant.
PRPriya Ramesh · Project Manager - Safety·10:44a·Near-missJOB-2214
Near-miss reported · unsecured guardrail, unit 214
Guardrail on unit 214 balcony found loose during morning walk. No injury. Toolbox talk delivered to framing crew. Corrective action logged.
MGMarcus Green · Safety officer - Inspection·11:10a·PassedJOB-2211
Rough plumbing inspection PASSED
Floors 1 & 2 rough plumbing signed off. Sticker photographed and filed. Cleared for insulation and drywall on Monday.
CoCity of New Orleans · Inspector — R. Fontenot - AI copilot·12:30p·AI · riskJOB-2212
Risk flag · potential scope creep on CE-14
Change Event #14 (owner-requested dock leveler upgrade) reviewed against contract allowance. Est. cost $47.2K vs. $29K allowance — variance ~$18.2K. Draft change order prepared for Denise K.
AFAI Field Copilot · Auto-generated